<?xml version="1.0"?>
<rdf:RDF xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:owl="http://www.w3.org/2002/07/owl#" xmlns:rdfs="http://www.w3.org/2000/01/rdf-schema#" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dcat="http://www.w3.org/ns/dcat#" xmlns:dct="http://purl.org/dc/terms/" xmlns:adms="http://www.w3.org/ns/adms#" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:time="http://www.w3.org/2006/time#" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:vcard="http://www.w3.org/2006/vcard/ns#"><dcat:Dataset rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset"><dct:title>Upscaling from single- to multi-filament dielectric barrier discharges in pulsed operation - Dataset</dct:title><dct:description><![CDATA[<p>A study on the scalability of discharge characteristics of a single-filament dielectric barrier discharge (DBD) to a spatially one-dimensional multi-filament arrangement driven by the same high-voltage (HV) pulses was performed for a gas mixture of 0.1 vol% O2 in N2 at 1 bar. Both arrangements feature a 1 mm gap with dielectric-covered electrodes featuring two hemispherical alumina caps for the single-filament and two parallel alumina-tubes for the multi-filament arrangement. The DBDs were characterised by electrical measurements (for peak current, energy, and power) accompanied by iCCD and streak imaging to determine the filament number and the discharge development in the gas gap and on the surfaces. The dataset contains the data presented in the corresponding journal article.</p>
]]></dct:description><dcat:keyword>basic research</dcat:keyword><dcat:keyword>streamer discharge</dcat:keyword><dcat:theme>Plasma Chemical Processes</dcat:theme><dct:identifier>51e4aceb-eb8c-44d4-ac6a-295fdbd79d84</dct:identifier><dct:issued>2022-08-26T14:00:32+02:00</dct:issued><dct:modified>2023-02-06T21:09:29+01:00</dct:modified><dct:language>en</dct:language><dct:publisher>INP</dct:publisher><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-0"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-1"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-2"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-3"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-4"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-5"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-6"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-7"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-8"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-9"/><dcat:distribution rdf:resource="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-10"/></dcat:Dataset><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-0"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 4a</dct:title><dct:description><![CDATA[<p>Applied voltage pulse for different pulse widths t_pulse.</p>
]]></dct:description><dct:issued>2022-08-26T14:00:53+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig4a.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>6534083</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-0</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-1"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 4b</dct:title><dct:description><![CDATA[<p>Applied voltage pulse for pulse width t_pulse = 0.2 µs with displacement current I_disp, total current I_tot and discharge current I_DBD in single-filament arrangement.</p>
]]></dct:description><dct:issued>2022-08-26T14:01:41+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig4b.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>71253</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-1</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-2"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 4c</dct:title><dct:description><![CDATA[<p>Applied voltage pulse for pulse width t_pulse = 0.2 µs with displacement current I_disp, total current I_tot and discharge current I_DBD in multi-filament arrangement.</p>
]]></dct:description><dct:issued>2022-08-26T14:02:25+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig4c.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>67058</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-2</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-3"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 5</dct:title><dct:description><![CDATA[<p>Voltage (U) and current characteristics of the applied 1 µs HV pulse and the corresponding discharge current I_DBD at both slopes for single- (SF) and multi-filament (MF) arrangement. The SF current is multiplied by a factor of 7.5.</p>
]]></dct:description><dct:issued>2022-08-26T14:03:09+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig5.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>985223</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-3</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-4"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 6</dct:title><dct:description><![CDATA[<p>Voltage (U) and discharge current (I_DBD) signals at the rising slope for single- (SF) and multi-filament (MF) arrangement. The SF current is multiplied by a factor of 7.5.</p>
]]></dct:description><dct:issued>2022-08-26T14:03:45+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig6.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>17239</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-4</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-5"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 7</dct:title><dct:description><![CDATA[<p>Maximal discharge current I_DBD_max at rising (RS) and falling (FS) slopes for single- (SF) and multi-filament (MF) DBDs in dependence on the HV pulse width t_pulse (obtained from 3077 single shots per data point).</p>
]]></dct:description><dct:issued>2022-08-26T14:04:16+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig7.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>761</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-5</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-6"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 8a</dct:title><dct:description><![CDATA[<p>Voltage (U) and charge (Q) for different pulse widths t_pulse in single-filament arrangement.</p>
]]></dct:description><dct:issued>2022-08-26T14:04:47+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig8a.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>15960893</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-6</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-7"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 8b</dct:title><dct:description><![CDATA[<p>Voltage (U) and charge (Q) for different pulse widths t_pulse in multi-filament arrangement.</p>
]]></dct:description><dct:issued>2022-08-26T14:05:29+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig8b.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>1312369</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-7</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-8"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 8c</dct:title><dct:description><![CDATA[<p>Consumed electrical energy E_el per period in dependence on the pulse width t_pulse for single-filament (SF) and multi-filament (MF) arrangement with uncertainty.</p>
]]></dct:description><dct:issued>2022-08-26T14:07:01+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig8c.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>136</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-8</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-9"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 11a-d</dct:title><dct:description><![CDATA[<p>Lateral profiles of discharge emission in the axial centre of the gas gap along the lateral position (x) for rising slope (RS) and falling slope (FS) of the HV pulse with different pulse widths t_pulse. Normalised values are  normalised with respect to the mean value of the plateau in the gap centre.</p>
]]></dct:description><dct:issued>2022-08-26T14:07:34+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig11a-d.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>93521</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-9</foaf:page></dcat:Distribution><dcat:Distribution rdf:about="https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-10"><dct:title>Upscaling from single- to multi-filament DBD - Fig. 12b</dct:title><dct:description><![CDATA[<p>Temporally integrated axial profiles at rising (RS) and falling (FS) slope of the HF pulse (t_pulse = 1 µs). x is the lateral position in the gap centre.</p>
]]></dct:description><dct:issued>2022-08-26T14:08:05+02:00</dct:issued><dct:modified>2022-08-26T14:14:07+02:00</dct:modified><dcat:accessURL rdf:resource=""/><dcat:downloadURL rdf:resource="https://inptdat.de/system/files/node572_Fig12b.csv"/><dcat:mediaType>text/csv</dcat:mediaType><dct:format>csv</dct:format><dcat:byteSize>16717</dcat:byteSize><foaf:page>https://inptdat.de/dataset/upscaling-single-multi-filament-dielectric-barrier-discharges-pulsed-operation-dataset-10</foaf:page></dcat:Distribution><foaf:Agent rdf:about="https://inptdat.de/publisher/n0"><foaf:name>DKAN</foaf:name><foaf:homepage>https://inptdat.de</foaf:homepage><dct:type rdf:resource="http://purl.org/adms/publishertype/NonProfitOrganisation"/></foaf:Agent></rdf:RDF>
